We recommend these Intermatic timers for most pools:Intermatic T101 Intermatic T103Intermatic T104Intermatic T103. Electrical Monke Aug 25, 2021 #22 It's broken. What Im wanting to do is just disable the turn off/on and just keep power 24/7. Put them back on and tighten them. Just above the yellow clock youll see some holes. Pool pump timers can last up to 20 years, depending on the model. It could also be loose wires, either on the time clock terminal board, or on the timer motor. The same happens prior to the timer reaching the off tripper. Terminal A (farthest to the left side) is not connected to anything. You could be missing the timer pins, you could have a bad timer, you could have no power to the timer or maybe even the timer is set wrong and it really is working but your not seeing it. Should it still not work, I suspect a motor failure for the clock. Could I send you a picture of my setup? P.S. Hi Andy, when a clock is running slow, we might assume power outages, but when it runs fast, we might assume either a 60 hz (US) timeclock hooked up to 50 hz power service (Europe), or vice-versa, or a manufacturing defect in the gear tolerances could cause a synchronous motor timer to run fast. White is usually neutral (for 115V power), and black/red are usually hot, but sometimes people dont always use the correct wire color. When I put the new one on, the trippers do not work. Other causes include rusted springs, insect infestation and loose timer dogs. Hi Fred, the only thought I have is that the cord should not be unplugged to turn off the pump, instead, rotate the dial until it turns off, because I dont believe there is a switch to turn off the timer. Generally the power goes from the breaker > Timeclock > pump, so that the power is always on to the clock. We had a storm last week and the yard flooded my pool so I went and switched the pool off at the breaker so it would not come on with the tabs until we were able to handle the pool. Homes similar to 2425 Glenview Dr are listed between $725K to $2M at an average of $385 per square foot. If power is reaching the clock, and the gears are turning, but the dial is not turning this means the gear on the back of the dial is not engaged. Would I suspect this is a defective motor? "image": {
If all looks well, and the gears are still not turning, you may need to replace the mechanism. Only perform this step if you are qualified. 120Volt Tork 1101 timers can be fixed with repair parts. Now ever sense I did that last week my timer wont shut off or turn on my pool pump. Miriam, I would check that the timer dogs are pushed fully onto the dial, and the dial is tight also check the screw for tightness in the center of the dial. The yellow clock face should sit down in the timer. You need that 8 hr run in just the summer . everything seems to be working correctly, but i can not turn the pump on or off by tripping the mechanism. I hope this helps. There are many reasons why your pool timer may not be working. If moving that is difficult, you could just avoid using the switch and turn the pump off with the timeclock instead, always keeping the switch on, and maybe taping the switch, to remind people not to use the switch. So what you will want to do now is to look for the circuit breaker panel and locate the circuit breaker for your Intermatic Pool Timer and then make sure it is set to the on position. IT happens, so I ask. My intermatic timer is not turning my pool pump on. If still not working, check the wire connections and then test voltage on the clock incoming wires, outgoing wires, and then at the pump motor the problem lies, where the power dies, as they say. Basically youre eliminating possibilities until you find the cause. If they are not moving then you have an issue. Sometimes the circuit breaker will trip again as soon as you reset it or even trip when the pump starts running. Hi Catherine, turning it on manually should not have damaged anything, so go easy on yourself It might have just been time to go. Push the tab on the top, and let the mechanism fall forward. And does the switch look worn, where the tripper engages? If so, is there power coming into the clock (on the line terminals)? Hotels near Time Tripper, Arcueil on Tripadvisor: Find 9,014 traveller reviews, 1,228 candid photos, and prices for 2,893 hotels near Time Tripper in Arcueil, France. Since it came out of the box today, it probably is not trash in the gears.It seems the plastic gears and/or the coil in the clock mechanism are not strong enough to engage the on/off points or not for long. So what you will need to do next is to troubleshoot your Intermatic timer with a few steps. 20 Reasons Why Pool Pumps Lose Pressure (and what to do), 25 Ways to Keep Ducks, Geese & Birds Out of Pool. it could also be a failing breaker, but that would be a last resort. If after verifying you have power to the timer, then check these things to further troubleshoot. Hi Rhomell, are you sure you got the correct trippers? You will first need to adjust the time on the timer first. Is there a separate switch somewhere between breaker and timer? The 240V or the T104 models have 5 brass screws (terminals) underneath the plastic insulator cover. Basically 12 real life hours equals about 14 on the timer. Did you find the issue? My original timer worked for 5 years then the clock stopped and I heard no sound. Can the pool timer be placed inside the garage to protect it from the harsh weather. The clock not turning on your Intermatic pool timer is a common issue. I have the same issue currently, and it makes no sense to me so far. AJH Trade Group also participate in other affiliate programs. See the wirig diagram in the owners manual here: https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf Clock motor power, as shown in the wiring diagram, comes from terminal 1 and also terminal 3. Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. The rest of your setup is probably fine. $829,900. There is power; gears are moving. Thank you. Check out the wiring diagram that comes with a new timer, or is printed on the door of the timer box. Hi Dave, my pool timers not working but when I look in the little window I do see the largest back gear turning (possibly the yellow time plate gear as that appears to be moving..yet not keeping correct time.) Followed all directions and even watched YouTube troubleshooting videos. Step 1 - Check that Timer is Functional Locate the two timer pins on your timer. I have a 2 speed pump. "address": "",
To check this, carefully inspect the gears for missing teeth and make sure they all freely turn. Monday the clock face was free spinning, today when I got home it had broken and fallen off. I also dont see any ants or other insects. Gently tighten the screws to securely hold the dogs in place. Having no power to your pool timer is a common problem and will occur because of three reasons: The first and easiest thing to check is the circuit breaker. Ordered new ones. Ft. 750 Joshua Dr, Hollister, CA 95023. I would shut off power to the clock while you spray, and release the tab at the top so you can spray behind the clock, and then find the nearby nest, and dig it up and add in some ant killer granular, or other method, to get the colony to move somewhere else. Hi Bob, you have two blacks and one neutral? ft. 975 Telegraph Rd #103, Santa Paula, CA 93060 $409,000 MLS# V1-15365 Hillview Estates, where you own the land, and this one has a big lot, over 4,100. The freeze protection on your clock, the probe may be bad or malfunctioning, and may be turning off the pump. Also be careful not to loosen the timer pins to much or they could fall off the timer wheel and onto the ground. hi, I have a smart pump for my pool, the time clock turns on in the morning and at the same time I see that the pump has power but it doesnt turn on, I have to turn on manually, is it something that the electrician has to connect to the pump so they are synchronized? If not, that sounds like a weak/bad motor. HELP! The A terminal is not normally used, unless you have a 3 wire service. The tabs on the back of the timer may have fused together, or the tabs on the stationary switch at the rear of the motor, from a power surge. the trippers are even slightly damaged the timer won't work correctly. Also, once it reaches the tripper, the gears in the window no longer move. Thanks for your help! We may earn a small commission. but ythe costs for T104 models vary greatlyHave ahayward 1 1/2 horsepower pump inground pool in Fl. Check to be sure that the yellow time dial gear on the back is engaged with the connecting gear, and pushed all the way in. ), you should be able to discern if this is the problem, which could mean a new clock. Deep down, I figured it was something I did wrong and it was. Once you figure out what is wrong with the timer, you may be able to do the repair yourself or might have to hire an electrician to come and replace the timer for you. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
Intermatic pool timers allow you to set specific run-times for your pool filter pump, booster pump, and waterfall pump, so they operate at the most convenient time, or during non-peak energy hours. The pump worked perfectly before I unscrewed it. If the pump comes on, you definitely have power to the timer. But no gears or any sound. To reset the time clock to the correct time, grasp the outer edges of the large yellow dial, and pull gently outward. After I replaced the motor with a 60Hz 277/208v motor the timer ran, but gained 1 hr/day. Did you try to flip the switch of the timeclock? PF1202T Freeze Protection Control Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control },
Any idea what may be causing this? Then number(time of day) that you line up with the time marker will be the time that you are setting your timer to. If the trippers are set for on and off pump function and nothing is working, reset the time and trippers. If you cant see an issue with the gears, then it could be the timer motor. "logo": {
Filter pump is ON at all timer Timer contacts welded Replace timer 5 . Terminals 2 and 4 are used for wires going to the load (pump). I noticed that they had stopped. 2303 RR 620 S #135-378 Lakeway TX 78734 USA (737)-210-8494 Sign in or Register Compare Gift Certificates Advanced Search Search Keyword Required Categories Automatically search sub categories Brands Search By Price Price Range From to Search By Setting If there is power going to the timer and the timer appears to be working but the pump isnt turning on and off, then youll need to check the pump. My timer doesnt seem to be working or my pump in either speed. Hi Mike, yes I sent you an email to your yahoo acct. how do I check the manual over ride switch to see if it is off? I used to run the pump for 8-9 hrs a day. Hi Doug, Check the wiring. All Rights Reserved. Move the switch and see that they separate when off, and come together when on. After a power failure the timer clock can start up backwards, mine has done this several times. please help me. Or fold the cover to one side if needed. Hi Alfred, I would guess that either the time dial is bent, or that the larger gear behind the dial is missing a tooth, at 10 pm, or has a bit of grit stuck in the gear at that point. Any guidance on how to fix this? You can replace the entire mechanism or the gears. Intermatic 156T1978A Timer Switch Trippers, Intermatic Timer Parts Replacement for T100 Series and Intermatic Time Clocks T101, T102, T103, T104, Pool Timer On Off Clips(4 ON / 4 Off / 8 Screws) : Amazon.com.au: Home Improvement I had a thunderstorm last night and my power went off for like 3 hours. After this has been removed, you can turn the breaker back on and measure for the voltage on the timer input. I have the Intermatic T103 autotimer on my pool. If you need to set the time, you will need to take two fingers and slightly pull the wheel towards you and away from the back of the timer box. Start with the easy checks. Look to see if the clock is set to the correct time. So either the tripper is broken (or installed out of alignment) or the tab (s) on the on/off switch are broken. About 1-2 years ago I swapped out this unit because it was sticking and not engaging when it was supposed to. It I set the timer again it will jeep time until it gets to the next dog ear. Commonly, many pool owners will think there pool timer is broken and not working when all they had to to is turn the circuit breaker to the on position. It has 4 screws below the dial labeled from left to right: LINE 1, LINE 2, LOAD 1, LOAD 2. If no damage is seen and the wires are intact, and the motor gears are not turning, and you find nothing stuck in the gears (sand, insects, any obstruction), and some spray WD-40 on the gears and a little push from a small flathead screwdriver does not help then, you can assume that the motor is dead, at which point you can replace the motor itself with the exact replacement, or replace the entire clock. Gears are moving , clock is seated correctly and everything is wired per diagram now that pool season is here I have to manually turn my pool on and off at the timer . If the pool timer is not keeping the correct time or losing time, there may be a simple fix. So what would be the problem? Assuming the wiring is all correct. Clean the gears with a toothbrush if you see debris or gunk in them. Just replace it and hope for one that isnt defective. We are on our third timer. HI Jeff, do you have power outages sometimes? I have the PF1202T timer on my pool. These clocks determine when your pool pump turns on, and how long it runs. A wire inside the motor may be touching another wire, or the metal sides of the motor. For Do-it-Yourself pool owners like yourself to make simple,, Sure, you could just replace your entire Hayward pump, but replacing only the motor is just as easy, and you don't have, Millivolt Pool Heater Troubleshooting Guide, https://www.intheswim.com/p/2-circuit-pool-timer, https://www.intheswim.com/p/24-hour-pump-timer, https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and . Advice? Just moved into my house and the pool pump continues to run even after tripping the timer mechanism. This div height required for enabling the sticky sidebar. TO SET "ON" AND "OFF" TIMES: Hold trippers against edge of CLOCK-DIAL, pointing to time (AM or PM) when ON and OFF operations are desired, tighten tripper screws firmly. 1100 Juanita St , Austin, TX 78704-5351 is a single-family home listed for-sale at $2,649,000. It should loosen up after a few goes when the grease and gunt dissolve. Read full answer 2/14/2023 3:20:07 AM We have a comprehensive article that covers what to do when the pump circuit breaker continually trips. If unsure, the White (Neutral) wire connects to the neutral buss bar in the breaker panel, and the Black (Line) wire would connect to the circuit breaker. Check that the breaker is firmly pushed onto the bar, and is not loose. Any ideas why its doing that? Another time clock that you can plug your pump directly into, and then plug the timer into the outlet, is the 24-hr Timer https://www.intheswim.com/p/24-hour-pump-timer (currently we are out of stock, but you can find at any home or hardware store). Hi Jeff, it could be that the terminals in the rear of the clock mechanism are fuse-welded together, and not separating like normal, when the on/off switch is flipped. I would suggest calling Intermatic and suggesting that idea and a free replacement? For some reason, whenever my timer hits the time its supposed to kick the pump on, it gets stuck at that time and the pump wont come on. Confused. If not, the motor may be failing. Your incoming power leads should connect to terminals 1 and 3, and the wires that lead to the pump, should be connected to terminals 2 and 4. That way I could schedule the pump once again. I have a PF1112T. Intermatic timers are a great addition to your pool set up but they can go wrong. Hi, These are the trippers that came with the time clock. The green tripper trips the mechanism closer to the center of the dial and the gold tripper trips the mechanism towards the outer edge of the dial. If your timer pins have not moved that means there is no power to the timer or the timer has failed and need to be replaced or possible manual over ride switch for the timer is off. "publisher": {
Phil. Two days ago after my pool pump shut off automatically I decided to turn it back on because the pool was still dirty. I have replaced the trippers, but the problem persists. Hello have a question some what related. The gears on my timer motor are clearly turning, but when the timer dog reaches the power-on lever, the switch wont flip. Or is there anything else I can check? Once you have confirmed that you timer is working you will need to adjust the timer pins to reflect the time you want your filter system to turn on and off. Either that or if an older clock, the motor may be failing, or the switch mechanism worn (the part that is tripped by the tripper). Jul 20, 2021. Also I have rotated the dial several times to trip on and off hoping that it lubricates the problem lever and dusts off the coil well. Use a power meter set on AC volts to verify the power is off, before handling the timer mechanism. what causes timer on/off pins to bend and how can i prevent timer pins from bending. Electricity is dangerous and can kill you if you dont know what youre doing. The instructions say THIS TIMER IS NOT TO BE USED AS A POWER DISCONNECT. Pool Timer Clock Parts and Trippers Welcome to Pool Spa Outpost! be sure the pins are pushed onto the edge of the dial fully. Turn on / off manually work fine, but The clock gears still not moving. Luis, it will, until it is switched to OFF, or until the OFF tripper shuts it off. I have changed the dog tripper and that does not take care of - Answered by a verified Electrician . Elite Swimming Pools TV 4.08K subscribers Subscribe 1.1K Share 97K views 3 years ago MIRAMAR Pool timer. Check that the TEST button has not popped out. "identifier": ""
Hi Phil, usually the OFF dog may not be fully pushed onto the dial, or if you examine it closely, it might be worn. "@context": "https://schema.org/",
Wired correctly, #10 wire, nothing. The pool timers I have had down there . The problem lies where the power dies, youve probably heard that before. Gas pool heaters are one of the best additions to a pool, but they are the most high-maintenance piece of equipment on, 22,000 pool parts in stock! Also, does it sound like the power is not leaving the breaker? Welcome to Pool Spa Outpost! If I manually flip the switch nothing happens. 2,767 Sq. At some time the timer was disconnected and the pump wired direct to the breakers. Yet another reason why timers dont work properly is the yellow clock wheel is not located or seated properly. Hi, Davy, seeing lots of complaints here. You will want to make sure the manual switch under the timer wheel is pushed to the on position. Do you have an answer to why my pump wont turn off or on? Everythings OK now, unit works just fine. However, since I did that the time clock stopped working I looked at the motor visual window and nothing is moving. Resolved! Eldon, the breaker should not be bad, but the timeclock may be wired incorrectly. I think I have found it. "caption": "In The Swim Blog"
Like # 8 09-16-07, 03:09 PM nap New Member Join Date: May 2006 Location: north Posts: 4,162 Depends maybe on what it is getting stuck on, or what is catching the tripper, and are the motor gears still turning when it gets stuck? Analog timers are the simplest type of pool pump timer and are easy to use (and the cheapest). There are 2 main facets to setting the mechanical timer for a pool pump, setting the time, and setting the on/off trippers. I have a white, red, and black wire coming from the power source. "@type": "ImageObject",
The pool was running on a timer. Repeat the process for the "on" pin. If its not, it wont work properly. Pop-in a new timer mechanism, and replace the wires to the previous configuration. It randomly loses the time that it is set to. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
The timer motor cover (the oval silver box with the printing) can be pried off with a sharp screwdriver. Tighten down all brass screws securely, to hold all wires firmly in place. But my new timer will not work either. They may be fused together, or could be a lizard stuck in there, or some other foreign object or insects. If you look closely, you should be able to discern if this is the problem, which could mean a new clock.
Korina Emmerich Net Worth,